Unboxing the Starter Kit.
Training materials
4 booklets to teach you how to use the material & make stents.
Sample material & exampe stent.
2 boxes of PerioPlast® (6 stents)
4 cubes make 1 stent.
Each box contains 3 stents.
Water Bath Kit
Water bath & cup holder.
2 steel cups & forceps.
#1
Setting up your water bath
What's in your Water Bath kit
water bath
cup holder
steel cup (2)
forceps
Water bath set-up
Quick check
Both cup and bath are now filled with water.
The water bath is ready to use when the water is steaming.
Cleaning the cup & bath
Steel cup
  • Use a clean cup for every patient.
  • Cup is autoclavable at 273°F or 134 °C.
Water bath
  • Can't be autoclaved.
  • Clean with sterilization wipes at least once a day.
Cup holder
  • Clean with sterile wipes.
#2
Making Making PerioPlast® mouldable
#2.1
Check if there’s water in both bath & cup. Turn the bath on at 180°F or 80°C.
#2.2
Wait until the water is steaming. This takes approx. 5 minutes.
#2.3
Put on gloves and apply Vaseline to prevent sticking.
Quick check
The material sticks together & feels like soft chewing gum.
You don’t feel individual granules anymore.
#2 - Set-up water bath
& heat PerioPlast
Next
#3 - Making your 1st Elemental stent
Continue
Upcoming
#4 - Clinical & financial implementation
Support & contact
Message us on Instagram
Call or text us
Text us on WhatsApp
Water bath set-up
& making PerioPlast® mouldable
To turn subtitles off/on, press 'CC' in the video settings.
Unboxing the Starter Kit
Training Materials
4 cubes make 1 stent.
Each box contains 3 stents.
2 boxes of PerioPlast® (6 stents)
4 cubes make 1 stent.
Each box contains 3 stents.
Water Bath Kit
Water bath & cup holder.
2 steel cups & forceps.
#1
Setting up your water bath
What's in your Water Bath kit
water bath
cup holder
steel cup (2)
forceps
Water bath set-up
Quick check
Both cup and bath are now filled with water.
The water bath is ready to use when the water is steaming.
How to clean the cup & bath
Steel cup
  • Use a clean cup for every patient.
  • Cup is autoclavable at 273°F or 134 °C.
Water bath
  • Can't be autoclaved.
  • Clean with sterilization wipes at least once a day.
  • See water bath manual for steam sterilization protocol.
Cup holder
  • Clean with sterilization wipes at least once a day.
#2
Making PerioPlast® mouldable
#2.1
Check if there’s water in both bath & cup. Turn the bath on at 180°F or 80°C.
#2.2
Wait until the water is steaming. This takes approx. 5 minutes.
#2.3
Put on gloves and apply some Vaseline to prevent sticking.
Quick check
The material sticks together & feels like soft chewing gum.
You don’t feel individual granules anymore.